Installation guide

2
2-12
EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows Environment
Planning, Miscellaneous Procedures, and Troubleshooting
This can be accomplished by the following procedure:
a. On POST when the QLogic HBA displays, press < Ctrl Q> for
Fast!Util.
b. Go to Configuration Settings > Host Adapter Settings > Toggle
down to Initiator iSCSI Name : Press Enter on the name and
type in the new name. ESC twice to get to Save Settings. Save
the settings. This will force a login to the storage device.
3. On the CLARiiON storage array register the new IQN name and
add it to your Storage Group.
Note: Only register one path. Ensure that the path is from the SP that the
lun belongs to. Failing to do so could result in a blue screen during the
installation process. Refer to the section on Preparing the Storage System
under Configuring a CLARiiON Boot Device. You can also refer to
CLARiiON documentation for a more detailed procedure for setting up
Storage Groups and Registering host names.
4. On the host in the QLogic Fast!Util, go to the iSCSI Boot Settings.
In Primary Boot Device press < Enter>. This will bring you to the
device list page. Select the DGC device that displays the RAID
level. Ensure that the iSCSI Boot field on that page is set to
Enabled.
5. Save all settings and reboot the host and load the Operating
System. Refer to Installing the Windows Operating System on
page 1-36.
6. After the Operating System is loaded and before the Initiator
Service is loaded, register the remaining paths on the CX storage
array. Install the Initiator Service. During the Microsoft Initiator
installation, deselect the Software Initiator, ONLY install the
Initiator Service. This will attempt to change the IQN name to fit
the Microsoft naming convention. Since this has been done in step
2, it will not blue screen the host for an inaccessible boot device.