EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows Environment
Installation and Configuration
Press Enter to return to the EFI shell. Type reset to reboot the server
to enable the changes.
Following the reboot, open the EFI shell. The Device Mapping Table
may be listed by default (similar to Figure 1-19 on page 1-23). If the
Device Mapping Table is not listed, type map and press Enter.
Figure 1-34 Example blkD as Array Port
Note any entries starting with "blk" (block-level devices, such as
volumes) which reference a Fibre interface (as shown in Figure 1-34).
The entry should list the array port WWN and LUN address specified
in the configuration utility. The example as shown in Figure 1-34
shows entry "blkD" as the array port WWN and LUN specified
during configuration). This is the EFI entry which specifies the
specific array LUN which will be used for boot.
Note: The example as shown in Figure 1-34 also shows BlkC as Lun0. This is
a Symmetrix-based read-only Volume Logix Database device used for LUN
masking, and cannot be used for boot, though it is still detected by the
QLogic EFI driver, and is reported as visible.
At this point, the OS Installation can begin using this LUN as the boot
volume.