Installation guide

1
Booting from the External Storage Array
1-31
Installation and Configuration
Find the driver handle numbers which correspond to those listed for
the QLogic HBAs (as shown in Figure 1-28 on page 1-30). Note the
two digits (proceeded by Ctrl, as shown in Figure 1-28) next to the
driver handles for the QLogic HBAs, these are control handles.
Determine the HBA instance which will be used for boot, and enter
the QLogic Fibre Channel Driver Configuration Utility by typing
drvcfg -s <driver handle> <control handle> (where "driver handle"
and "control handle" are the values which correspond to the HBA
instance which will be used for boot. In this example, "
drvcfg -s 5f
62
" would be used) and pressing Enter.
Figure 1-29 Fibre Channel Driver Configuration Utility
The Fibre Channel Driver Configuration Utiliity Menu will be
displayed (as shown in Figure 1-29).
Type 1 (Edit Adapter Settings) and press Enter.