Installation guide
1
1-18
EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows Environment
Installation and Configuration
Figure 1-12 Select Fibre Channel Device Window
If no entries appear at any target IDs, verify the following:
◆ If multiple HBAs are present, verify the HBA select in the BIOS
Utility is the same which currently provides the I/O path to the
storage (at this point, only one I/O path should be configured to
the boot LUN)
◆ For CLARiiON arrays, verify that the single I/O path points to
the SP which owns the boot LUN
◆ For FC-SW environments, verify fabric zoning parameters, such
that a single I/O path exists to the boot LUN (see array software
documentation for details)
◆ Check physical FC connectivity between the HBA and array
(direct attach environment) or switch (FC-SW environment)
Select the array port to be used for boot, and press Enter. If LUNs
have been allocated to the HBA (using LUN Masking schemes, such
as Access Logix or Volume Logix), they will be presented at their
LUN number.