Installation guide

2
2-28
EMC Fibre Channel and iSCSI with QLogic HBAs in the Windows Environment
Planning, Miscellaneous Procedures, and Troubleshooting
Special Instructions for CLARiiON CX200-Series Direct-Connect
Dual-Host Clustering Configurations
For CLARiiON CX200-Series direct-connect dual-host cluster
configurations only with QLA234x HBAs, you must follow all
procedures described in this section.
Check for an Updated
HBA Driver
For CLARiiON CX200-Series direct-connect dual-host cluster
configurations with only QLA234x HBAs, you may need a separate
driver and firmware download. The EMC Support Matrix notes
whether separate driver and firmware files are required.
For each HBA that is determined to require updated firmware and
drivers, follow the instructions on page 2-2. Be sure to reference the
Name and Description fields to select the correct CX200-Series
direct-connect dual-host cluster-compatible files.
Reconfigure the HBA
Jumper
For CLARiiON CX200-Series direct-connect dual-host cluster
configurations with only QLA234x HBAs, you must change the
default HBA optic jumper position:
CAUTION
!
Modifying the jumper setting without using the recommended
firmware/drivers can cause the HBA to lose connectivity.
1. Remove the HBA from the server as instructed by your server
guide.
2. Locate jumper(s) J3 (QLA2340) or J3 and J4 (QLA2342), shown in
the following figure: