User`s guide

7 – Setting Up Connections
Configuring LUNs for a Device
FS0054601-00 E 7-21
Q
NOTE: This option is available only when the LUN is enabled and there are at
least two available paths.
7.3.2.3.1
Configure Adapter LUN Paths to the Default
Perform the following steps to configure all LUN paths for an adapter to the default
values:
1. For the adapter for which you want to configure the LUNs, right-click in the
Adapter n heading.
2. From the pop-up menu, select Configure Adapter Using Default.
7.3.2.3.2
Configure an Individual LUN’s Paths to the Default
Perform the following steps to configure an individual LUN’s paths to the default
values:
1. For the LUN that you want to configure, right-click in the cell in the LUN, Enable,
or Device Port Name column.
2. From the pop-up menu, select Configure Path Using Default.
7.3.2.4
Setting Individual LUN Paths
Perform the following steps to set a LUN path as the preferred or alternate path in
a failover condition. You can also select the preferred or alternate path as the
currently active path.
1. From the LUN Configuration dialog box, right-click in the cell in the Adapter n
column.
2. From the pop-up menu, select one of the available options.
Select Set LUN to Preferred to set the alternate path as the preferred path
in a failover condition.
Select Set LUN to Alternate to set the preferred path as the alternate path
in a failover condition.
Select Set Path to Current to set this preferred or alternate path as the
currently active path.