Product specifications

5 Using QLview for Fibre Performing Diagnostics
FC0051101-00 A 5-29
7. In the Continuous Testing field, select one, both, or neither of the following:
Continuous Testing to have testing continue even if errors occur.
Stop on Error to halt testing when an error occurs.
8. Click Loopback Test or Read/Write Buffer Test.
If you select continuous testing, a dialog displays while the test is running,
which enables you to click Cancel to stop the test.
5.7.2.1
Loopback and Read/Write Buffer Test Results
The Test Result field in the Loopback and Read/Write Buffer Diagnostics window
displays the results of a test run (see figure 5-23):
Figure 5-23. Test Result Field
The Test Status column indicates whether the test passed or failed. The remaining
information pertains to error counters.