62 Implementing an Open IBM SAN
10.From the Extended Firmware Settings menu, scroll down to Connection
Options to open the Option and Type of Connection window.
11.Select one of the following options:
a. 0: Loop only
b. 1: Point-to-point (preferred setting)
c. 2: Loop preferred (If you cannot use arbitrated loop, then default to
point-to-point)
d. 3: Point-to point, otherwise loop (If you cannot use point-to-point, default
to arbitrated loop).
12.Press Esc.
13.Save the changes. Highlight Yes.
14.Restart the server.
1.11.4 Downloading the current Fibre Channel adapter driver
Perform the following steps to load the current driver onto the QLogic adapter
card.
1. Go to the following Web site:
www.qlogic.com
2. From the home page, click Driver Download.
3. Click Use QLogic Drivers.
4. Click IBM Enterprise Subsystems Division approved drivers.
5. Click IBM Approved QLA22xx drivers or IBM Approved QLA21xx drivers.
6. Click Link to Drivers.
7. In the window for File Download, click Save this Program to Disk.
8. Insert a floppy diskette into your floppy disk drive.
9. In the field for Save in, change the drive letter to A:\
10.Create a folder called Temp in the Save As window.
Note: If you connect the ESS directly to the host system, the option you select
must match the port connections on the ESS. However, if you connect through
a switch, the options do not need to match the port connections because the
ESS is point-to-point. The appropriate HBA on the server must also support
point-to-point connection on a direct connection. Currently, disparate vendors
do not function properly in a direct point-to-point connection. This statement is
not true if you connect through a switch because the ESS is point-to-point.