User`s guide
Chapter 1. Implementing Fibre Channel host adapter cards 39
l. Disable database load: No
m. IOCB allocation: 256
n. Extended error logging: Disabled (might be enabled for debugging)
8. Press Esc to return to the Configuration Settings menu.
9. From the Configuration Settings menu, scroll down to Extended Firmware
Settings. Press Enter.
10.From the Extended Firmware Settings menu, scroll down to Connection
Options to open the Option and Type of Connection window.
11.Select one of the following options:
a. 0: Loop only
b. 1: Point-to-point (preferred setting)
c. 2: Loop preferred (If you cannot use arbitrated loop, then default to
point-to-point)
d. 3: Point-to point, otherwise loop (If you cannot use point-to-point, default
to arbitrated loop).
12.Press Esc.
13.Save the changes. Highlight Yes.
14.Restart the server.
1.9.12 Downloading the current Fibre Channel adapter driver
Perform the following steps to load the current driver onto the QLogic adapter
card.
1. Go to the following Web site:
www.qlogic.com
Note: The Enable LIP reset, Enable LIP full logon, and Enable target reset
parameters control the behavior of the adapter when Windows NT tries to do a
SCSI bus reset. You must perform a target reset to make cluster failovers
work.Use the SCSI bus device reset option to clear SCSI reservations.
Note: If you connect the ESS directly to the host system, the option you select
must match the port connections on the ESS. However, if you connect through
a switch, the options do not need to match the port connections because the
ESS is point-to-point. The appropriate HBA on the server must also support
point-to-point connection on a direct connection. Currently, disparate vendors
do not function properly in a direct point-to-point connection. This statement is
not true if you connect through a switch because the ESS is point-to-point.