User`s guide

8–Fibre Channel Interactive Commands
Read Write Buffer Test
SN0054667-00 B 8-25
Please Enter Selection: 1
Read Write Buffer Test
1: Display Test Parameters
2: Reset Test Parameters
3: Configure Test Parameters
4: Start Diagnostics Test
Display Test Parameters (-kr)
2. Read Writer Buffer Test<port selection>1. Display Test Parameters
From the Read Write Buffer Test menu, select the Display Test Parameters
option to view the read write buffer test parameters. For example:
--------------------------------------------------------------------------------
HBA Instance 0: QLE2462 Port 1 WWPN 21-00-00-1B-32-17-F9-C4 PortID 00-00-00
--------------------------------------------------------------------------------
--------------------
Diagnostics Settings
--------------------
Data Pattern : Random
Data Size (Bytes) : 8
Number of tests (1-10000): 10000
Test Increment(1-10000) : 1
Abort On Error : Ignore
Test Continuous : OFF
------------------------------------------------------------------------
Reset Test Parameters
2. Read Write Buffer Test<port selection>2. Reset Test Parameters
From the Read Write Buffer Test menu, select the Reset Test Parameters option
to reset the read write buffer test parameters to their default values.
Configure Test Parameters (-kr)
2. Read Write Buffer Test<port selection>3. Configure Test Parameters
From the Read Write Buffer Test menu, select the Configure Test Parameters
option to open the Read Write Buffer Test submenu with options to configure the
data pattern, data size, number of tests, test increment, error handling, and
devices. For detailed information about these parameters, see Table 5-6.
For example:
Loopback Test
=======================================================
HBA : 0 Port: 1
SN : GFC0718P57753
HBA Model : QLE2462