User`s guide
5–Fibre Channel Noninteractive Commands
-s (Silent Mode)
SN0054667-00 B 5-33
To save the adapter parameters to a file, issue the following command:
# qaucli -pr fc -r (<hba instance> | <hba wwpn>) save <File Name>
Where:
-s
(Silent Mode)
In noninteractive mode, the system shows result and status messages generated
by QConvergeConsole CLI (by default) unless suppressed by silent mode. You
can combine this option with the -o option (see ==“-o (Output to a File)” on
page 5-28) so the output is saved in a file and does not appear in the CLI. For
example:
# qaucli -pr fc -I all -s -o output.txt
-sp
(Update Adapter Firmware)
To update the adapter firmware SerDes table with a file, issue the following
command:
# qaucli -pr fc -sp <hba instance> | <hba wwpn> <file name>
To save the adapter firmware SerDes table to a file, issue the following command:
# qaucli -pr fc -sp <hba instance> | <hba wwpn> save
<file name>
Where:
hba instance = Adapter number (use -g command to find)
hba wwpn = World wide port name of the adapter
hba parameters file
name
= File name or a path to a file to save the adapter parameters
NOTE:
The -s option is valid only in noninteractive mode.
You can use this option with all noninteractive mode options that have a
corresponding interactive mode option (see Table 5-1). This option must
be the first or last command in the command line.
hba instance = Adapter number (use -g command to find)
hba wwpn = World wide port name of the adapter
file name = Name of the firmware preload table DAT file.