Product specifications

B–Assigning LUNs to the MPX200 for Data Migration
Assigning LUNs from an MSA1000/1500 Array
ISR654605-00 A B-5
To assign LUNs:
1. Perform zoning as follows:
a. Connect the Fibre Channel ports of the data migration appliance to a
switch where the storage controller ports are also logged.
b. Using switch management tools, create a zone DM_Host_MSA1000,
and then add the WWPN of the data migration appliance Fibre
Channel ports and storage controller ports in this zone.
c. Save the zoning information and activate the new zoning configuration.
2. Open the Array Configuration Utility.
The Configure Available Device(s) window appears, as shown in Figure B-4.
Figure B-4 Configure Available Device(s)
3. In the right pane under Common Tasks, click Selective Storage
Presentation, and then click Enable.
A list of the WWPNs seen by the MSA controller appears, as shown in
Figure B-5.