Product specifications
ISR654605-00 A B-1
B Assigning LUNs to the
MPX200 for Data Migration
For successful completion of data migration, you must assign source and
destination LUNs to the MPX200 using storage array management tools. The
MPX200 appears as a host to the array controller. This appendix provides
procedures for using some of the array management tools to assign LUNs,
including:
Assigning LUNs from an MSA2012fc Array
“Assigning LUNs from an MSA1000/1500 Array” on page B-4
“Assigning LUNs from an HDS Array” on page B-7
“Assigning LUNs from an IBM DS4K/DS5K/LSI Array” on page B-12
“Assigning LUNs from an EVA 4/6/8000 Series Array” on page B-16
“Assigning LUNs from an EMC CLARiiON Array” on page B-20
Assigning LUNs from an MSA2012fc Array
To assign LUNs:
1. Perform zoning as follows:
a. Connect the Fibre Channel ports of the data migration appliance to a
switch where the storage controller ports are also logged.
b. Using switch management tools, create a zone DM_Host_MSA2012,
and then add the WWPN of the data migration appliance Fibre
Channel ports and storage controller ports in this zone.
c. Save the zoning information and activate the new zoning configuration.
Storage Vendor HP
Array Model
MSA2012fc arrays
LUN Assignment Tool
Storage Management Utility user interface