Product specifications

2–Inventory Checklists
Step 5: List and Create Fibre Channel Zoning
2-4 ISR654605-00 A
Table Notes
You should complete the information for the source and destination LUN during the planning phase of data migration.
Determine the unique volume ID for the source storage array to make it easier to refer to the LUN, because sometimes
on large arrays, different LUNs with the same LUN ID are presented to different hosts.
Each MPX200 has up to four virtual port groups (VP Groups), each of which can be seen by an array as a different
host entity. You can expose the different LUNs as the same LUN ID on each VP Group, enabling you to maintain the
same LUN ID exposure to both the host and the MPX200.
Step 5: List and Create Fibre Channel Zoning
For a Fibre Channel SAN, create a list of fabric zones that contain the WWPN
associated with servers, storage arrays (source and destination) and MPX200, as
shown in Table 2-5. The destination array should be zoned in only with the
MPX200 before migration. After migration, the destination arrays should be zoned
in with servers, as shown in Table 2-6.
Table 2-5. Pre-Migration Fibre Channel Zoning Information
FC Switch and
IP Address
FC Zone Name Zone Members (WWPNs)
Server, MPX200,
Storage Name
Table 2-6. Post-Migration Fibre Channel Zoning Information
FC Switch and
IP Address
FC Zone Name Zone Members (WWPNs)
Server, MPX200,
Storage Name