Installation guide
4–Configuration
Configuring Fibre Channel Array Hosts and LUN Assignments with the iSR6200
ISR651101-00 C 4-15
Figure 4-12 Correctly Assigning LUNs to your VPG Host Entities
Figure 4-13 shows presenting LUN 3 incorrectly. If an iSCSI host logged into both
VPG0 and VPG1, it would have access to LUN 3 through two virtual port groups.
This is invalid and will lead to serious problems.
iSR6200
Storage Array
Blade 1
21:00:00:c0:dd:13:16:f8
21:01:00:c0:dd:13:16:f8
21:02:00:c0:dd:13:16:f8
21:00:00:c0:dd:13:16:f8
21:00:00:c0:dd:13:16:f9
FC1
FC2
Host Entities
Host Entity 0
21:01:00:c0:dd:13:16:f8
21:01:00:c0:dd:13:16:f9
Host Entity 1
21:02:00:c0:dd:13:16:f8
21:02:00:c0:dd:13:16:f9
Host Entity 2
21:00:00:c0:dd:13:16:f9
21:01:00:c0:dd:13:16:f9
21:02:00:c0:dd:13:16:f9
LUN 1
LUN 2
LUN 3
LUN 4