Installation guide

C–Log Messages
C-34 ISR651101-00 C
184542 FcipRoute#%d: VLAN Info Unavailable FCIP Info Route definition includes VLAN but the network
VLAN device instance does not exist. This is an inter-
nal error. Try removing the route definition and
re-enter the route definition.
200721 QL3022:ql3xxx_probe: Adapter eth#%d,
Invalid NVRAM parameters
TOE Fatal A GE port (eth#%d) has invalid NVRAM parameters.
204835 QL3xxx:eth%x PHY Downshift occurred TOE Error The Ethernet device could not successfully communi-
cate with the link peer at the highest negotiated port
rate. Check the Ethernet cabling and Ethernet switch
statistics of the corresponding port.
204837 QL3xxx:eth%x Link Down TOE Error The Ethernet link is down. Check the Ethernet
cabling and Ethernet switch or remote peer statistics.
217124 QL3xxx:eth%x Link Up TOE Info The Ethernet link is up.
233473 "memory monitor: Detected Uncorrectable
Ecc %08lx system is rebooting in 5 secs\n"
System Fatal Uncorrectable memory error detected at address pro-
vided in log message.
233474 "Failed to register interrupt handler!\n" System Fatal Attempt to register the interrupt handler failed.
233475 "%s class_simple_create failed\n" System Fatal Failed class_simple_create system call from
memory monitor initialization routine.
237572 "Failed to kill sys killer %d\n" System Error Failed to kill system task.
237573 Temperature over high threshold %d System Error The router temperature has exceeded the high tem-
perature threshold.
Table C-1. iSR6200 Router Log Messages (Continued)
ID Log Message
Module
Typ e
Msg.
Typ e
Description