User`s guide

5 – Configuring CHAP
Discovery SessionBi-directional CHAP
5-2 SN0054660-00 A
S
Discovery SessionBi-directional CHAP
To configure a bi-directional CHAP during a discovery session:
1. On the bridge, enable CHAP for the iSCSI port.
2. Select the port in the left column.
3. Click Advanced Configuration.
4. Select Enable Chap.
5. Type a secret in Chap secret (for example, secret_port).
6. Check to see if the initiator exists on the discovered iSCSI initiators list:
If the initiator is not part of the discovered iSCSI initiators list, then go
to the wizard menu and select Add Initiator Wizard.
If the initiator is part of the discovered list, then go to Step 10.
7. Type the IQN name string.
8. Select Enable CHAP.
9. Create a CHAP secret (for example, secret_initiator).
10. Go to the MS Initiator and perform the following steps:
a. Click General.
b. Click Secret (in the middle of the screen).
c. If this is the first time you are setting secrets, reset all secrets.
d. Type the CHAP secret (secret_port) that you created in Step 5.
11. Click Discovery.
12. Click Add.
13. Enter the address of the iSCSI port of the bridge.
14. Click Advanced.
15. Select Chap Login Information.
16. Type the secret (secret_initiator) that you created in Step 9 into Target
Secret.
17. Select Mutual Authentication.
18. Click OK.
19. Click OK. The initiator completes discovery.