Technical data

DATA CENTER TECHNICAL BRIEF
Setting Up NPIV with Brocade HCM and Microsoft Hyper-V 12 of 12
To get this detail, run the FOS CLI command nsShow on the switch. In this example, the source is the
virtual port 28:92:00:05:1E:65:8A:CB (Physical Disk 3).
nsShow displays a lot of detail, so to help find the information, use
nsshow | more
This displays the data one page at a time.
In this example, these are the details for the source ID (the Hyper-V guest).
N 012303; 3;2f:bd:00:05:1e:65:8a:cb;20:00:00:05:1e:65:8a:cb; na
FC4s: FCP
PortSymb: [92] "Brocade-825 | 1.1.0.1 | F02-HP3 | Windows Server (R) 2008
Enterprise | Service Pack 1hyperv3"
Fabric Port Name: 20:23:00:05:1e:58:1e:dc
Permanent Port Name: 10:00:00:05:1e:65:8a:cb
Port Index: 35
Share Area: No
Device Shared in Other AD: No
Redirect: No
Source ID ( Source PID)
Source WWN (Physical disk 3)
Port Number
In order to understand how to set this up, you need to understand how perfTtMon works (Top Talkers). The
I/O transferred is in terms of what the switch sees. In a server/storage configuration, the port is considered
the ingress and the storage the egress. So by adding an ingress to the port number of a server, this is
considered the writes from the server to the storage. If you added an egress on the port with the storage,
this would be reads on the server. In this example, writes to the storage device from the server are shown.
Perfttmon –add ingress 35 (the port with the virtual port).
Perfttmon –show 35. By default, only a certain number of Top Talkers are listed at any one time. If
there are several NPIV ports on a physical port, you will need to show more of the NPIV ports by running
perfttmon –show 35 x (where x is any number). This command does not run continuously, you
have to run it manually. This command samples once every 30 sec and then averages the values. The
first time you run the command, you may see no data, which means either there is no data running, or
that you need to wait longer for the data to be crunched.
Src_WWN Dst_WWN MB/sec
===========================================================================
28:92:00:05:1e:65:8a:cb 20:70:00:c0:ff:d5:86:c7 2.784
2f:bd:00:05:1e:65:8a:cb 20:70:00:c0:ff:d5:86:c7 0.000
NOTE: Two ports are listed: the first one i
s the virtual port and the second is the other virtual port on that
physical port. Since the physical port is not listed (nor zoned), no traffic is being used by the physical port.
© 2009 Brocade Communications Systems, Inc. All Rights Reserved. 04/09 GA-TB-163-00
Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron,
SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM and SAN Health are trademarks of
Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service
names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning
any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes
to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes
features that may not be currently available. Contact a Brocade sales office for information on feature and product availability.
Export of technical data contained in this document may require an export license from the United States government.