Product specifications

5 – Virtual HBA (NPIV) Port Creation and Verification
Verify Virtual HBA Port Login to FC Switch
FC0054604-00 A 5-3
a
5. A dialog box displays, prompting for a password. Type the password
previously set for SANsurfer FC HBA Manager. If the default password has
not been changed, type config.
6. If the vPorts have been created successfully, the final SANsurfer FC HBA
Manager screen will be similar to Figure 5-4.
Figure 5-4. SANsurfer FC HBA Manager vPort Created Successfully
Verify Virtual HBA Port Login to FC Switch
At this point, the virtual HBA port has been successfully created and logged into
the FC switch. You can double-check the new virtual HBA port by viewing the
Name Server information of the Fibre Channel switch attached to the QLogic FC
HBA port.
To view the Name Server information, use the QLogic Enterprise Fabric Suite™
(EFS) 2007 application. EFS 2007 allows you to configure, manage, and
troubleshoot a QLogic SANbox Fibre Channel switch.
The following paragraphs and illustrations show what the Fibre Channel switch
Name Server log looks like before and after creating a virtual HBA port.