Product specifications
5 – Detailed Descriptions of Command LineTools
Fabric Analysis Tools
5-50 D000006-000 Rev A
Q
5.4.3.5.5
Obtain very detailed information about IOUs
NOTE: To shorten the length of the output, the following example focuses on only
1 IOC.
[root@duster root]# iba_report -o ious -F ioc:'Chassis 0x00066A005000010C, Slot 2, IOC 2' -d 5
IOU Summary Focused on:
Ioc: 2 0x00066a02300001e0 Chassis 0x00066A005000010C, Slot 2, IOC 2
in Node: 0x00066a00580001e0 CA VEx in Chassis 0x00066a005000010c, Slot
1 IOUs in Fabric:
Name: VEx in Chassis 0x00066a005000010c, Slot 2
NodeGUID: 0x00066a00580001e0 Type: CA
Ports: 2 PartitionCap: 64 SystemImageGuid: 0x00066a00580001e0
BaseVer: 1 SmaVer: 1 VendorID: 0x66a DeviceID: 0x5a44 Rev: 0xa1
1 Connected Ports:
PortNum: 2 LID: 0x0013 GUID: 0x00066a02580001e0
Neighbor: 0x00066a00280002cd 3 SW InfiniCon Systems InfiniFabric
(Sw A Dev A)
PortState: Active PhysState: LinkUp DownDefault: Pollig
LID: 0x0013 LMC: 0 Subnet: 0xfe8000000000000
SMLID: 0x0001 SMSL: 0 RespTimeout: 33 ms SubnetTimeout: 56 ms
M_KEY: 0x0000000000000000 Lease: 0 s Protect: Readonly
MTU: Active: 2048 Supported: 2048 VL Stall: 0
LinkWidth: Active: 4x Supported: 1-4x Enabled: 1-4x
LinkSpeed: Active: 2.5Gb Supported: 2.5Gb Enabled: 2.5Gb
VLs: Active: 1+1 Supported: 4+1 HOQLife: 4096 ns
Capability 0x02090048: CR DM CM SL Trap
Violations: M_Key: 0 P_Key: 0 Q_Key: 0
ErrorLimits: Overrun: 15 LocalPhys: 15 DiagCode: 0x0000
P_Key Enforcement: In: Off Out: Off FilterRaw: In: Off Out: Off
Max IOCs: 3 Change ID: 9 DiagDeviceId: 0 Rom: 0
IocSlot: 2 GUID: 0x00066a02300001e0
ID String: Chassis 0x00066A005000010C, Slot 2, IOC 2
IO Class: 2000 SubClass: 66a Protocol: 0 Protocol Ver: 1
VendorID: 0x66a DeviceID: 0x30 Rev: 0x1
Subsystem: VendorID: 0x66a DeviceID: 0x30
Capability: 0x33: ST SF WT WF
Send Depth: 2 Size: 256; RDMA Read Depth: 0 RDMA Size: 4294967295
2 Services:
Name: InfiniNIC.InfiniConSys.Control:02
Id: 0x1000066a00000002
Name: InfiniNIC.InfiniConSys.Data:02
Id: 0x1000066a00000102
1 Matching IOUs Found
5.4.3.5.6
Identify connections and links composing the fabric
[root@duster root]# iba_report -o links
Link Summary
20 Links in Fabric:
Rate NodeGUID Port Type Name
10g 0x00066a00280002cd 3 SW InfiniCon Systems InfiniFabric (Sw A Dev A)
<-> 0x00066a00580001e0 2 CA VEx in Chassis 0x00066a005000010c, Slot 2
10g 0x00066a00280002cd 5 SW InfiniCon Systems InfiniFabric (Sw A Dev A)
<-> 0x00066a10280002cd 4 SW InfiniCon Systems InfiniFabric (Sw A Dev B)
10g 0x00066a0098000001 1 CA julio
<-> 0x00066a00d8000123 8 SW InfiniCon Systems InfinIO9024