User Manual

44
must not be stored in garage or any other enclosed area. Only store in venti-
lated area!
Storage of heater indoors is permissible only if the cylinder is disconnected
and removed from the heater.
Check the tightness of the gas valve and for damage. If you suspect a dama-
ge, have it changed by your gas dealer.
Never store liquid gas cylinder in a sub-terrain, or at places without adequate
air ventilation.
CLEANING AND CARE
Warning: Make sure the heater is in off position and is cool!
Warning: Do not clean heater with cleaners that are combustible or corrosive.
Wipe off powder coated surfaces with soft, moist rag and soap water.
Remove debris, spider and insect nests from ventilation opening of the cylin-
der enclosure, control compartment, burner and circulation air passageways
of the heater with heavy duty pipe cleaner or compressed air to keep appli-
ance clean and safe for use.
Never clear ports or other openings with toothpicks or other article that will
break and block the ports.
TROUBLESHOOTING
Problem Cause Solutions
The motor does not
work
No electricity supply Check the terminal board
with a tester
The safety thermostat
is on
Wait about one minute then
restart
The motor works, but
the burner does not
light up and after few
seconds the heater
stops
The cylinder gas tap is
closed
Open the gas tap
The cylinder is empty Use a new cylinder
The nozzle is obstruct
-
ed
Remove the nozzle and
clean it.
The solenoid gas valve
is not open
Check that the solenoid
valve works
There is no spark Check the position of elec
-
trode
The burner lights up
but after few seconds
the heater stops
No connection with
the earthing system
Check and connect properly
Defective connection
between sensor and
safety device
Check and connect properly
Defective safety device Replace the safety device
The heater stops
during operation
Excessive gas supply Check the pressure reducer
and if required replace it
Insufficient air flow Check that the motor works
properly
Insufficient gas supply
due to ice formation
on the cylinder
Check and use a larger
cylinder or two cylinders
connected together.
4