Operation Manual
andrequired(set)humidityarememoriseduntilpowersupplyisrestored.
PROTECTION AGAINST EXTREME HIGH OR LOW TEMPERATURE
1
When sensor on the air intake detects ambient temperature ≤0°Cor≥40°C,the
dehumidifierwillshutoffautomaticallyforprotectionreasonsandproducesa
continuousacousticalalarmsignalwith3longand2shortsignals.
When sensor detects ambient temperature ≤0°C:“0°C”isshownintheLCDdisplay.
When sensor detects ambient temperature ≥40°C:“40°C”isshownintheLCDdisplay.
2
When sensor on the evaporator detects its temperature ≥40°C,thedehumidifierwill
shutoffautomatically(protection),andthesymbolofautomaticdefrost
illuminates.
Inthisprotectionmode:
• Controlbuttonsdonotlongerfunction.Removethepowercordplugfrommains
and reposition it again to restart the unit.
• Aftertheprotectionmodeofextremelylow&hightemperature,theappliancewill
notkeepitsmemoryfunctionwhenrestart.
AIR FILTER
Thedehumidifiersareequippedwitha3-layerfilterpackagetocleanthecirculatedroom
air.The3-layerfilterpackageconsistsofascreenfilterand(separatelypacked)3M™HAF
andactivecarbonfilter.Thesefiltersmustbeplacedaccordingtotheinstructionsbefore
operating the dehumidifiers.
Picture7
1
Screenfilter;toremovebiggerdustparticles.
2
3M™HAFfilter;toremoveunhealthyparticlesfromtheairsuchaspollen,bacteria,
animal dander and dust.
3
Activecarbonfiltersheet;toremoveodours.
4
89