User Manual

23
SHORTCUT OPERATIONS
Offset Frequency Direction Setup
Under standby state, press key, the top left corner of LCD displays " " icon,
press key to choose offset frequency direction. There are 3 options, Positive
offset, Minus offset, shut off offset.
(+) Positive offset:1. Indicates TX frequency is higher than RX frequency. When
enable reverse function, the RX frequency is higher than TX frequency.
(-) Minus offset:2. Indicates TX frequency is lower than RX frequency. When
enable reverse function, the RX frequency is lower than TX frequency.
None:3. Indicates shut offset off.
Under frequency mode (VFO) or channel mode, press key then press key to choose positive offset
direction(+), minus offset direction (-) , shut offset off one by one (Please refer to offset frequency setup).
NOTE: This function is unavailable in professional transceiver mode.
Frequency/Channel Scan
Under corresponding mode, press key, the top left corner of LCD displays " " icon, then press
key to start frequency scan or channel scan.
Frequency Scan1.
Under VFO mode, frequency scan is available. This function is used for monitoring
signal of various communication frequency by transceiver ‘step’ setup, press
numeric key or
key to exit.
Channel Scan
2.
Under channel mode, this function is used for monitoring signal of each channel