User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
InnoSight Ultrasound System
2D Mode Image Controls
inen
9
P6992-4, EN, 16/12/6
Adjusting Time Gain Compensation (TGC)
Adjust the gain which compensates for the attenuation (a reduction in sound amplitude) of the echo signals
in proportion to their depth (based on travel time)
Touch TGC to display the TGC sliders on the screen To increase/decrease the gain at the desired section
(depth) of the image, drag the corresponding slider to the right/left
Adjusting the Scan Depth
Adjust the field of view To view larger or deeper structures, increase the depth To enlarge the display of
structures near the skin line, decrease the depth The system automatically adjusts the frame rate (FPS) and
acoustic power indices (TI/MI) based on the scan depth
Touch Depth +/- or flick horizontally on the scan area to set the scan depth
Adjusting the Focus Depth, Focal Zone and Focal span
Focus optimizes the image by increasing the resolution for a specific area and is displayed by a red arrow
marker indicated at the depth ruler Depending on the transducer in use and the mode selected, multiple
focus depths can be added Increasing the number of focal zones decreases the frame rate If the frame
rate is not high enough, try decreasing the number of focal zones
Touch Focus +/- to adjust the depth value Touch Focal Zone +/- to select the desired number of focal
zones Touch Focal Span +/- to adjust the distance between the focal zones
Adjusting Dynamic Range
Control the range of acoustic levels displayed in the image, which affects the contrast of the image
Touch Dyn Range +/- to adjust the amount of compression
Using Tissue Harmonic Imaging (THI)
Reduce superficial artifact and provide better gray scale contract by processing an integer multiple of the
fundamental frequency, a harmonic wave
Touch THI to enable this function
Adjusting Persistence
Adjust the amount of frame averaging from real-time images or loops Higher persistence produces less
speckled and smoother image but reduces the temporal resolution
Touch Persist +/- to adjust the value
Adjusting Sharpness and Smoothing
Improve the sharpness of the image by enhancing the edge contrast and smoothening the tissue speckle
Touch XRES +/- to adjust the value
Adjusting Gray Map
Change how the amplitude is converted to brightness
Touch Gray Map +/- to adjust the value