User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
1
einnx
Adding Measurements
InnoSight Ultrasound System
P6992-4, EN, 16/12/6
Slope
Measure the length between the intersections of two cursors Slope can be positive or negative and
measures the rate of change between the two points defined by the intersections of the cursors in cm/sec
1 Touch Slope A crosshair cursor with horizontal and vertical axes appears on the time series window
Drag the cursor to a desired start point and release it
2 A second cursor appears Drag it to the end point then release it to complete measurement
The slope measurement is not restricted to either the horizontal or the vertical axis of the start
marker
Time
Measure the length between two vertical time lines created by two cursors The position of the horizontal
distance lines does not affect time measurements
1 Touch Time A crosshair cursor with horizontal and vertical axes appears on the time series window
Drag the cursor to a desired start point on the horizontal axis and release it
2 A second cursor appears Drag it to the end point on the horizontal axis then release it to complete
measurement
Heart Rate
Measure the length between two vertical lines created by two cursors in beat per minute (BPM) The
position of the horizontal distance lines does not affect the heart rate
1 Touch Heart Rate A crosshair cursor with horizontal and vertical axes appears on the time series
window Drag the cursor to a desired start point on the horizontal axis and release it
2 A second cursor appears Drag it to the end point on the horizontal axis then release it to complete
measurement
Measuring in Spectral Doppler Mode
Auto Trace
Trace the spectrum of Doppler waveforms
Touch High Q The trace for the Doppler spectrum will be performed automatically with measurements
calculated and displayed on the screen
Semi-Trace
Trace the Doppler spectrum with better accuracy in the measurement calculation
1 Touch Semi Trace A crosshair cursor with vertical axis appears on the time series window Drag the
cursor to a desired peak of the graph and release it
2 A second cursor appears Drag it to end diastole on the graph then release it
3 A third cursor appears Drag it to the second peak of the graph and release it
4 Touch anywhere on the screen to complete the trace
To obtain an accurate auto-trace and measurement result, a quality Spectral Doppler image with
clean noise background is required