User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
77
einnx
Adding Annotations
InnoSight Ultrasound System
P6992-4, EN, 16/12/6
2 Type the texts directly Touch Done on the keyboard to finish inputs
3 Drag the text cursor to where you want the new texts to be, and release it to place the texts
b
Setting the Text Home Position
You can choose a specified position in the image display as the starting location, which is the text home
position
1 Move a set of existing texts to the desired text home position
2 Touch the texts directly, and touch Done to close the keyboard
3 Touch Set home
To restore the texts to the default text home position, simply touch the texts, close the keyboard,
then touch Go home
Label
1 Touch Label A predefined text menu appears at the control panel area
c
, and a text cursor (I-beam)
appears at the text home position
2 Select a text label to place it at the current cursor position, and touch Close
3 Drag the cursor/label to where you want the texts to be
The text labels are still editable Touch the label to display the virtual keyboard, and start editing
the texts Touch Done on the keyboard to finish editing
Body Mark
1 Touch Body Mark to display the body mark menu
Distance
Ellipse
Angle
IMT
Annot
Arrow
Report
Freeze Acquire
Fn Key Set start Set end Home
Menu
End Exam
1 56
Abdomen
12/5/2016 08:56 AM
1
C6-2
MI 0.72
TIS 0.03
33 Hz
16.0 cm
2D
Gen
Gn 43
DR 78
1/ 0/ 1
3/ 0/ 6
Body Mark (7)
Close Erase
Figure 24Add a body mark