User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
67
inee
DICOM Configuration
InnoSight Ultrasound System
P6992-4, EN, 16/12/6
2 Assign a name to the server and enter it in the Name field
3 Enter the IP Address, Port and AE Title specified by your network administrator in the respective fields
4 To test the server connection, touch Test in the Echo Test section A verification message confirms a
successful connection within a few seconds
Repeat step 1-4 to add more servers based on your needs
If you add a second storage SCP, when you export an exam or an image/video to the DICOM
server, two tasks are created in the outgoing queues
To start exams by loading patient information in a worklist, you need to configure the worklist
SCP first
Consult your network administrator about the appropriate settings
Local Host
In the Local Host section, touch Edit
The system’s default Name and IP Address, if connected successfully to the network, display in the
respective fields
In the AE Title field, enter the application entity title of your system, which identifies you as the sender and
must be unique on its network
Consult your network administrator about the appropriate settings
Managing Outgoing Queue
When you export an exam or an image/video to the DICOM server, you can monitor its status in the
outgoing queue The system provides three ways of exporting the exam For more information, see
Exporting the Exam on page
Task status icon* Description
Upload is pending
Upload is processing
Upload is complete
Upload failed
If you export an exam as a report, the task status icon includes
In the Outgoing Queue section, touch Edit
To re-send the task to the DICOM server, touch Retry
To cancel the ongoing task, touch Stop
To clear all tasks from the outgoing queue, touch Clear all