User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
59
inee
Identifying the Main Screen Layout
InnoSight Ultrasound System
P6992-4, EN, 16/12/6
2D Color PW
M CPA
Focus8.0
Dyn Range78
THI Full Screen
Dual Toggle
Freeze Acquire
Fn Key iScan TGC Home
2D
Menu
End Exam
Pen Res
Transducer
MI
TIS
16
17
15
18
19
20
21
22
25
26
27
28
24
23
5
Figure 9Real-time imaging screen (example)
No. Function No. Function
15
ROI (region of interest) area
Use the Zoom function to zoom in and pan
across the current image
16
End Exam button
Close the current exam for the current
patient, and start a new exam for the next
patient All the value settings adjusted during
this exam will be stored automatically
17
Res (High Resolution): Drag the cursor to
the right for a clearer yet superficial image
Pen (Deep Penetration): Drag the cursor to
the left for a deeper yet less clear image
18
Home button
Return to the real-time imaging screen
19
TGC (Time Gain Compensation)
Slide any of the TGC sliders to adjust the gain
for the desired section of the 2D image
20
iScan button
Optimize the image quality during a real-time
scan
21
Fn Key button
Assign this button as a shortcut to perform a
function
22
Thumbnail area
Thumbnails of the scanned images/loops that
are saved Flick vertically to scroll through the
list
23
Acquire button
Save a default set of image frames as a loop
to the system hard drive
24
Scan mode (image control) buttons
When using duplex or triplex modes, touch
the scan mode (image control) buttons here
to display and adjust its corresponding image
control settings
27
25
Freeze button
Freeze the current scan
26
Open the next page of the image control
settings (See page 6)
27
Image control settings (See page 9)
28
Scan mode buttons
The system does not allow acquiring images/loops with no patient name and ID A temporary patient
name will be added if you proceed with saving