User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
131
12 Appendix
Appendix B: Connectivity and Security
InnoSight Ultrasound System
P6992-4, EN, 16/12/6
Port for DICOM communication (typically port 14, 262 or 11112 to specify the port, on the
system’s imaging screen, touch Menu >Settings > DICOM
Port for HTTP web servers (not supported by the system)
Anti-virus software is not installed on the system
Information Flow
InnoSight
Worklist
server
PACS
server
Worklist query
Worklist response
DICOM storage/Echo request
Echo response
Figure 43Information flow
Read the system’s DICOM Conformance Statement for detailed instructions DICOM conformance
statements for Philips products are available at this website:
wwwhealthcarephilipscom/main/about/connectivity/dicomconformancemainwpd
IT Network Failure Recovery Measures
IT network connection stability depends on many factors Unreliable connection may later lead to failure
and cause the following hazardous situations
Any connection of the equipment, this system (InnoSight) or/and other systems, to the IT network risks the
unidentified data leakage of the patients, operators or third parties It is recommended to set up the device
in a secure network and behind the firewall The potential risks and suitable countermeasures are evaluated
and identified in the following table before connecting the equipment to an uncontrolled IT network
Therefore, you must evaluate and identify all potential risks as well as prepare suitable countermeasures
before connecting the equipment to an uncontrolled IT network For guidance addressing these risks, refer
to IEC 1-1:21