User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
InnoSight Ultrasound System
Appendix B: Connectivity and Security
12 Appendix
13
P6992-4, EN, 16/12/6
Item Specifications
Water resistant level IP21
Efficiency Eff (av)
Safety Approved according to IEC 661-1 Edition 3
EMC IEC 661-1-2, IEC 6124-3, EN 11 Class B
Protection
OVP (Over Voltage Protection), SCP (Short Circuit Protection), OCP (Over
Current Protection)
Features
Highest output power on the market of wall plug adapters
Exchangeable AC-plugs for universal use
Suitable to power up medical systems up to BF class
Appendix B: Connectivity and Security
Introduction
To exchange ultrasound images and patient data, the system conforms with the Digital Imaging and
Communications in Medicine (DICOM) standard and can therefore be connected to Picture Archiving
and Communication System (PACS) and Modality Worklist (MWL) The former allows the system to store
the acquired examination data (static images or image loops) in PACS, while the latter allows the system
to query examination orders from the MWL server and start the examinations In order to achieve the
purposes above, the system offers two ways of connecting to the IT network, hard-wired LAN and wireless
LAN connections, for DICOM communication
To ensure the data security, use an IT network isolated from the external environment by a
firewall
Specifications
Hardware
211 a/b/g/n, Gigabit Ethernet
Software
The system is connected to PACS and MWL by DICOM standard
Read the system’s DICOM Conformance Statement for detailed instructions
Security
The system has no listening ports open to the WLAN interface So a network entity cannot initiate a
connection to the system from the WLAN However, the system can initiate a connection to servers on the
WLAN, Gigabit Ethernet and beyond Computer access to the system through the USB port is blocked
The system allows connection via Bluetooth with limited devices (HID) only
Use the following TCP/IP ports for outgoing communication to the WLAN and Gigabit Ethernet