User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
InnoSight Ultrasound System
Appendix A: Specifications
12 Appendix
12
P6992-4, EN, 16/12/6
Item Specifications
Accessories
Power adapter
Input: AC 1 24V, 6Hz, Max 1A
Output: 19Vdc, 34A
Transducer
S4-2, L12-4, C6-2, C9-4v
System cart
Support Tilt and Swivel oints, Height Adjustment, Instant dock and
undock function
Storage/transport
Temperature: -2 6C
Humidity 2 9 RH
Air pressure 16hPa
Environmental operating
conditions
Temperature: 1 4C
Humidity: 2 RH, no condensation
Air pressure: 16 hPa
Product life years
Battery
Model: QIC3
Battery type (non-removable): 3S2P Panasonic-3mAh, compliant with IEC62133 standard
Item Rate performance Remark
Battery Cell 3 mAh Panasonic
Typical capacity Above 614 mAh Rate discharge capacity after rate charge
Nominal capacity Above 33 mAh Rate discharge capacity after rate charge
Nominal voltage 1 V
Mean operation voltage during rate discharge after
rate charge
Maximum charge voltage 126 V CV mode charging voltage
Voltage at end discharge 9 V Stop discharge when any cell reaches tc 2 2 V
Suggested charge current
(Standard)
12 A
Suggested charge current
(maximum)
3 A
Suggested continuous
discharge current
3 A
33 W
Suggested maximum
discharge current
A
W
END of charge condition 1 mA 1 min
Operating temperature
4C
1 4C
- 6C
Standard charging
In max charging
Standard discharging