User's Manual
Table Of Contents
- 1 Read This First
- 2 Safety Information
- 3 Overview
- 4 Preparing the System
- Inserting a microSD Card
- Using the Stand
- Charging the System
- Connecting the Transducer
- Removing the Transducer
- Using the System On The Go
- Using the Wheel Brakes
- Placing the Transducer Holder
- Mounting the System to the System Cart
- Adjusting the System Cart Height
- Connecting an External Printer
- Tilting the System
- Unmounting the System From the System Cart
- Moving the System
- Outputting the System Display to an HDMI-Enabled TV or Monitor
- Supported External Printers
- 5 Using the System
- Turning On/Off the System
- Logging Into the System
- Launching the Main Screen
- Setting the System Time and Date
- Controlling the System
- Setting the System Language
- Identifying the Main Screen Layout
- Switching the Control Panel Pages
- Managing the System Power
- Managing Disk Space
- Network Configuration
- DICOM Configuration
- 6 Performing an Exam
- Starting a New Exam
- Adding a New Patient
- Loading a Worklist
- Selecting a Preset
- Setting the Transducer Orientation
- Selecting/Switching a Scan Mode
- Adjusting the Displayed Image
- Freezing an Image
- Adding Annotations
- Adding Measurements
- Saving and Printing the Image
- Reviewing the Image
- Exporting the Exam
- Managing the Exam List
- Ending the Exam
- 7 Using Image Controls
- 2D Mode Image Controls
- Overview
- Adjusting Gain
- Adjusting Frequency
- Adjusting Time Gain Compensation (TGC)
- Adjusting the Scan Depth
- Adjusting the Focus Depth, Focal Zone and Focal span
- Adjusting Dynamic Range
- Using Tissue Harmonic Imaging (THI)
- Adjusting Persistence
- Adjusting Sharpness and Smoothing
- Adjusting Gray Map
- Adjusting Chroma Map
- Adjusting Steer Angle
- Adjusting the Sector Width and Position
- Adjusting Power
- Using Trapezoidal Imaging
- Adjusting Density
- Using Compound Imaging
- Using ENV (Enhanced Needle Visualization)
- Color/CPA Mode Image Controls
- M-Mode Image Controls
- Spectral Doppler Mode Image Controls
- 2D Mode Image Controls
- 8 System Customization and Service
- Customizing Your System
- Configuring Security Policies
- Servicing your system
- Reinstalling Software
- Checking the Software Version
- Checking the System’s Serial Number
- Checking the Tablet’s Serial Number
- Checking the License Status
- Resetting User Settings
- Backing Up System Settings and Patient Data
- Restoring System Settings and Patient Data
- Resetting Your System
- Testing the System
- Exporting System Logs
- Reading the User Manual
- 9 Transducers
- 10 Transducer Care
- 11 System Maintenance
- 12 Appendix
InnoSight Ultrasound System
nde
Transducer Storage
110
P6992-4, EN, 16/12/6
Transducer Storage
Use the appropriate guidelines for storing transducers for transport, and daily and long-term storage For
information on temperature and humidity requirements, see Appendix A: Specifications on page 12
Storage for Transport
If a carrying case is provided with your transducer, always use the carrying case to transport the transducer
from one site to another Follow these guidelines to properly store transducers for transport:
Make sure that the transducer is clean and disinfected before placing it in the case to avoid
contaminating the foam that lines the carrying case
Place the transducer in the case carefully to prevent kinking of the cable
Before closing the lid, make sure no part of the transducer is protruding from the case
Wrap the case in plastic material containing air-filled pockets (such as Bubble Wrap material), and pack
the wrapped case in a cardboard carton
Daily and Long-Term Storage
Follow these guidelines to protect your transducer:
Always store transducers in the transducer holders on your system cart or on a securely mounted wall
rack when you are not using them
Ensure the transducer holders are clean before storing transducers
Avoid storing transducers in areas of temperature extremes or in direct sunlight
Store transducers separately from other instruments to avoid inadvertent transducer damage
Before storing transducers, make sure they are thoroughly dry