Install Manual

10 11
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO ML-G10.X – Q CELLS INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO ML-G10.X – Q CELLS
2 PLANNING
2.3 MOUNTING OPTIONS
Ä The below mounting options are only possible under certain conditions.
MODULE TYPE
MOUNTING
OPTION
POSITION OF CLAMPS*
[IN (MM)]
TEST LOAD
PUSH / PULL***
[PA]
DESIGN LOAD
PUSH / PULL***
[PA]
SAFETY
FACTOR
Q.PEAK DUO ML-G10
Q.PEAK DUO ML-G10+
Q.PEAK DUO ML-G10.2
Q.PEAK DUO ML-G10.4
Q.PEAK DUO BLK ML-G10
Q.PEAK DUO BLK ML-G10+
Q.PEAK DUO ML-G10.a
Q.PEAK DUO ML-G10.a+
Q.PEAK DUO BLK ML-G10.a
Q.PEAK DUO BLK ML-G10.a+
CL2a
(with rails)
0.79 - 3.94 (20 - 100)**** 2400 / 2000 1600 / 1330
1.5
0.79 - 11.8 (20 - 300)**** 2400 / 1800 1600 / 1200
CL2b (with-
out rails)
0.79 - 7.87 (20 - 200) 2000 / 2000 1330 / 1330
0.79 - 11.8 (20 - 300) 1800 / 1800 1200 / 1200
*
**
***
****
Distance between outer edge of module and middle of the clamp; consider further details below.
Loads according to IEC 61215-2:2016 and UL 61730.
Test procedure according to IEC 61215-2:2016 and UL 61730. Mounting options do not fulfill the requirements of the standards.
Rails must not be under the junction box.
2 PLANNING
2.3 MOUNTING OPTIONS
Specifications
MODULE TYPE
MOUNTING
OPTION
POSITION OF
CLAMPS* [IN (MM)]
TEST LOAD
PUSH / PULL**
[PA]
DESIGN LOAD
PUSH / PULL**
[PA]
SAFETY
FACTOR
Q.PEAK DUO ML-G10
Q.PEAK DUO ML-G10+
Q.PEAK DUO ML-G10.2
Q.PEAK DUO ML-G10.4
Q.PEAK DUO BLK ML-G10
Q.PEAK DUO BLK ML-G10+
Q.PEAK DUO ML-G10.a
Q.PEAK DUO ML-G10.a+
Q.PEAK DUO BLK ML-G10.a
Q.PEAK DUO BLK ML-G10.a+
CL1a
5.12 - 13.8 (130 - 350) 5400 / 4000 3600 / 2660
1.5
0.79 - 19.7 (20 - 500) 5400 / 3600 3600 / 2400
0.79 - 25.6 (20 - 650) 2400 / 2400 1600 / 1600
CL1b 11.8 - 19.7 (300 - 500) 2400 / 2400 1600 / 1600
CL3 9.45 - 13.8 (240 - 350) 4000 / 4000 2660 / 2660
FB1 15.6 (395.5) 5400 / 4000 3600 / 2660
FB2 15.6 (395.5) 4000 / 4000 2660 / 2660
IP1 -
3600 / 3300 2400 / 2200
CL5
short side: 0.79 - 3.94
(20 - 100)
long side: 11.8 - 17.7
(300 - 450)
CL6c
outer clamps: 0.79 - 19.7
(20 - 500)
middle clamps: 25.2 -
48.8 (640 - 1240)****
3600 / 3600 2400 / 2400
CL6d
short side: 0.79 - 9.7
(20 - 250)
long side: 25.2 - 48.8
(640 - 1240)****
4000 / 3600 2660 / 2400
MOIUNTING OPTIONS REQUIREMENTS
All
Ä The loads in the table are related to the mechanical stability of the solar modules. The mechanical
stability of the mounting system including clamps has to be evaluated by the system supplier. The
listed test load values have been determined with the following clamp parameters: clamp width =
1.57 in (40 mm) and clamp depth = 0.39 in (10 mm).
Ä The system installer is responsible for the determination of location-specific load requirements.
Ä Ensure that the connection cables of the junction box do not run between laminate and mounting
rails.
Ä Modules bend under load. Therefore, sharp objects (e.g. screws, ballast stones, rail ends, rails with
burrs or sharp corners) must not be placed near the module backside so as not to touch the laminate
under load.
Ä Ensure that the junction boxes do not touch the mounting structure (e.g. shorts rails, ballast, etc.)
or the rooftop under load. Clamps or insertion profiles etc. must not touch the glass (even under
load).
Ä Unbalanced loads (e.g. snow overhangs, snowdrifts) which result in locally significantly increased
loads must be removed or avoided by technical measures.
CL1a, CL2a, CL3,
FB1, FB2
Ä Ensure that module frame is fixed directly on the rail of the substructure (no spacer allowed between
the module and substructure).
CL1a
Ä With push test loads of 5400 Pa: The clamp position is variable in the given range but the distance
between the clamps along the long side of the module (span) must not be larger than 55.12 in (1400
mm).
CL1b
Ä Using of short mounting rails are permissible, if they overlap under the module less than 8.27 in (210
mm). Minimum clearance between frame bottom edge and roof top must be ≥ 1.38 in (35 mm).
CL1b, CL2b, CL3,
FB2, CL6c, CL6d
Ä A minimum support depth of 0.59 in (15 mm) is required on the back side of the module.
CL5
Ä The minimum required support depth on the module backside is 0.39 in (10 mm) on long frame side
and 0.59 in (15 mm) on short frame side.
IP1
Ä Ensure minimum support depth of 0.59 in (15 mm) on the backside and 0.39 in (10 mm) on the front
side of the module.
FB1, FB2
Ä Use M8 corrosion-proof screws and washers (diameter ≥ 0.62 in (15.8 mm)) for mounting slots
(Detail A, Fig.1). Mounting screws and washers should have the same material properties.
CL6c, CL6d
Ä Use of short mounting rails under the modules are permissible, if they do not touch the laminate
under load.