Install Manual

8 9
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO ML-G10.X – Q CELLS INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO ML-G10.X – Q CELLS
Fig. 3: Installation options for crystalline Q CELLS modules. All dimensions are given in inch (mm in brackets). Also observe
the maximum test loads and clamping range as specified on the following page.
The illustrated installation options apply for both horizontal and vertical module orientation.
Module Clamp Subconstruction Mounting profile
TYPE OF
INSTALLATION
MODULE POINT MOUNTING SYSTEM LINEAR MOUNTING SYSTEM
INSTALLATION
WITH CLAMPS
Q.PEAK DUO ML-G10
Q.PEAK DUO ML-G10+
Q.PEAK DUO ML-G10.2
Q.PEAK DUO ML-G10.4
Q.PEAK DUO BLK ML-G10
Q.PEAK DUO BLK ML-G10+
Q.PEAK DUO ML-G10.a
Q.PEAK DUO ML-G10.a+
Q.PEAK DUO BLK ML-G10.a
Q.PEAK DUO BLK ML-G10.a+
HYBRID
CLAMPING
Q.PEAK DUO ML-G10
Q.PEAK DUO ML-G10+
Q.PEAK DUO ML-G10.2
Q.PEAK DUO ML-G10.4
Q.PEAK DUO BLK ML-G10
Q.PEAK DUO BLK ML-G10+
Q.PEAK DUO ML-G10.a
Q.PEAK DUO ML-G10.a+
Q.PEAK DUO BLK ML-G10.a
Q.PEAK DUO BLK ML-G10.a+
2 PLANNING
2.3 MOUNTING OPTIONS
11.8 - 17.7
(300 - 450)
NA
0.79 - 3.94
(20 - 100)
CL5
CL2a
0.79 - 11.8
(20 - 300)
CL2b
0.79 - 11.8
(20 - 300)
CL2a
0.79 - 11.8
(20 - 300)
CL2b
0.79 - 11.8
(20 - 300)
0.79 - 25.6
(20 - 650)
North
America
11.8 - 19.7
(300 - 500)
CL1a
CL1b
0.59 - 8.27
(15 - 210)
CL3 CL4
0 - 11.8
(0 - 300)
9.45 - 13.8
(240 - 350)
7.87 - 13.8
(200 - 350)
North
America
CL3 CL4
0 - 11.8
(0 - 300)
TYPE OF
INSTALLATION
MODULE POINT MOUNTING SYSTEM LINEAR MOUNTING SYSTEM
INSTALLATION
ON MOUNTING
POINTS
Q.PEAK DUO ML-G10
Q.PEAK DUO ML-G10+
Q.PEAK DUO ML-G10.2
Q.PEAK DUO ML-G10.4
Q.PEAK DUO BLK ML-G10
Q.PEAK DUO BLK ML-G10+
Q.PEAK DUO ML-G10.a
Q.PEAK DUO ML-G10.a+
Q.PEAK DUO BLK ML-G10.a
Q.PEAK DUO BLK ML-G10.a+
INSTALLATION
WITH INSERTION
PROFILES
Q.PEAK DUO ML-G10
Q.PEAK DUO ML-G10+
Q.PEAK DUO ML-G10.2
Q.PEAK DUO ML-G10.4
Q.PEAK DUO BLK ML-G10
Q.PEAK DUO BLK ML-G10+
Q.PEAK DUO ML-G10.a
Q.PEAK DUO ML-G10.a+
Q.PEAK DUO BLK ML-G10.a
Q.PEAK DUO BLK ML-G10.a+
NOT PERMITTED
2 PLANNING
2.3 MOUNTING OPTIONS
IP1 IP2
IP1 IP2
NA
CL6c
0.79 - 19.7
(20 - 500)
CL6d
0.79 - 9.8
(20 - 250)
25.2 - 48.8
(640 - 1240)
25.2 - 48.8
(640 - 1240)
NA
CL6c
0.79 - 19.7
(20 - 500)
CL6d
0.79 - 9.8
(20 - 250)
25.2 - 48.8
(640 - 1240)
25.2 - 48.8
(640 - 1240)
NA
4 × mounting
slots
15.6
(395.5)
FB2
4 x mounting
slots
NA
15.6
(395.5)
FB1
The module is considered to be in compliance with UL 61730 only when the module is either mounted in the manner specified by
the mounting instructions, or when the mounting means has been evaluated with this PV module to UL 2703. A module with exposed
conductive parts is considered to be in compliance with UL 61730 only when it is either electrically grounded in accordance with the
manufacturer’s instructions and the requirements of the National Electrical Code, ANSI/NFPA 70 (2014-2017), or when the bonding
means has been evaluated with this module to UL 2703.