5. Electrical Requirements Before Spa Delivery
IMPORTANT PLEASE READ!
When installed in the United States or Canada, the electrical wiring
of this spa must meet the requirements of the National Electric Code
(NEC) and any applicable state, providence, or local codes. The
electrical circuit must be installed by an electrical contractor or
licensed electrician, and approved by a local building/electrical
inspector.
Electrical setup before delivery of your spa
1. All 240 Volt spas must be permanently connected (hard wired) to
the power supply. Supplying power to the spa which is not in
accordance with these instructions will void both the
independent testing agencies listing and the manufacturer’s
warranty.
2. The power supplied to the spa must be a dedicated circuit
with no other appliances or lights sharing the power.
3. To determine the current, voltage and wire size required for
the spa configuration to be connected:
y Wire size must be appropriate per NEC and/or local codes.
(Minimum #6 wire Required)
y Wire size is determined by length of run from breaker box to spa
and maximum current draw.
y Minimum #6 copper wire with THHN insulation.
y All wiring must be copper to ensure adequate connections. Do
not use aluminum wire.