User Manual
MIL-PRF-55310/29C
6
Vibration, sinusoidal: In accordance with MIL-PRF-55310 and method 204 of MIL-STD-202.
Nonoperating: Test condition D.
Operating: Not required.
Shock, non-operating: Method 213 of MIL-STD-202, condition I.
Thermal shock: Method 107 of MIL-STD-202, condition B.
Ambient pressure:
Nonoperating: In accordance with MIL-PRF-55310.
Operating: Method 105 of MIL-STD-202, test condition C.
Storage temperature: In accordance with MIL-PRF-55310.
Reflow soldering: Reflow soldering of the unit at +230°C ± 10°C for 15 seconds shall not degrade the performance.
Moisture resistance: Method 106 of MIL-STD-202.
Pad strength: In accordance with method 2004 of MIL-STD-883, condition D.
Solderability: Method 208 of MIL-STD-202.
Resistance to solvents: Method 215 of MIL-STD-202.
Screening: In accordance with MIL-PRF-55310, class B or S, as applicable.
Part or Identifying Number (PIN): Consists of “M” prefix followed by specification sheet number, a dash and coded
alphas, and numeric number. See example:
EXAMPLE
M55310/29- S 01 A XXXXXXXX
M prefix and specification sheet number
Product level (S, B, or C)
Dash number (see table I)
Operating temperature range
(A, B, or C) (see table I)
Frequency