User Manual
MIL-PRF-55310/26D
6
TABLE I. Dash numbers and operating characteristics.
1/ See figure 3.
2
/ Up to 30 days following shipment, see table II.
3
/ No load condition.
4
/ After 30 days following shipment, see table II.
TABLE II. Frequency aging limits
.
1
/ See table I.
Dash
number
Output
frequency
range
Input
current
(max) at
5.0 V
10% 3
/
Pulse characteristics
1
/
Initial
accuracy
at 23C
1C
2
/
Frequency
aging per
year (max)
4
/
Initial frequency
temperature accuracy
Config-
uration
Rise/fall
time
(max)
Duty
cycle
min-max
-55C
to
+125C
-55C
to
+105C
-20C
to
+70C
A B A B C
percent ppm ppm ppm ppm ppm
02 03 .01 MHz to
1.0 MHz
10 mA 10 ns 45 to 55
15 5 65 55 40
06 07 .01 MHz to
1.0 MHz
10 mA 10 ns 45 to 55
25 10 100 75 50
22 23 1 MHz to
4 MHz
15 mA 10 ns 45 to 55
15 5 65 55 40
26 27 1 MHz to
4 MHz
15 mA 10 ns 45 to 55
25 10 100 75 50
32 33 4 MHz to
20 MHz
20 mA 10 ns 40 to 60
15 5 65 55 40
36 37 4 MHz to
20 MHz
20 mA 10 ns 40 to 60
25 10 100 75 50
42 43 20 MHz to
35 MHz
35 mA 10 ns 40 to 60
15 5 65 55 40
46 47 20 MHz to
35 MHz
35 mA 10 ns 40 to 60
25 10 100 75 50
52 53 35 MHz to
50 MHz
40 mA 5 ns 40 to 60
15 5 65 55 40
56 57 35 MHz to
50 MHz
40 mA 5 ns 40 to 60
25 10 100 75 50
62 63 50 MHz to
65 MHz
70 mA 5 ns 40 to 60
15 5 65 55 40
66 67 50 MHz to
65 MHz
70 mA 5 ns 40 to 60
25 10 100 75 50
5 ppm per year 1/ 10 ppm per year 1/
Maximum change over 30 days
0.7 ppm 1.5 ppm
Projected maximum change
for 1 year after 30 days
5.0 ppm 10.0 ppm