MIL-PRF-55310/8J
4
TABLE I. Dash numbers and operating characteristics.
Frequency-voltage tolerance: 2 ppm maximum for a 10 percent change in supply voltage. Measurements taken
at reference temperature and operating temperature range end points.
Frequency aging: Measurements shall be taken at +70C 0.2C at intervals of not more than every 72 hours for
30 days minimum.
5 Hz to 4.9 MHz
5MHz to 50 MHz
1 ppm per 30 days, maximum. 2 ppm per 30 days, maximum
2 ppm per 90 days, maximum. 2
/ 4 ppm per 90 days, maximum
5 ppm per year, maximum. 2
/ 10 ppm per year, maximum
Terminal strength: Method 211 of MIL-STD-202
, test condition A.
Applied force: 2 pounds each terminal for 10 seconds.
Bends: Five at 45 degrees each.
Frequency-environmental tolerance: Not applicable.
2
/ This is a performance requirement of the oscillator. Support data shall be presented showing that this
requirement shall be met.
Dash
number
Output
frequency
range
Supply
voltage
Input
current
(max)
Output voltage Rise
and
fall
times
(max)
Duty
cycle
at 1.4 V
Frequency-temperature
tolerance (ppm)
Logic: 1
(min)
Logic: 0
(max)
-55C
to
+125C
-55C
to
+105C
-20C
to
+70C
A B C
V dc mA ns percent
01 1 kHz to
150 kHz
+5
0.25
158 15 45 to 55
50 40 25
02 150 kHz to
300 kHz
+5
0.25
94 15 45 to 55
50 40 25
03 300 kHz to
600 kHz
+5
0.25
94 15 45 to 55
50 40 25
04 600 kHz to
2.5 MHz
+5
0.25
50 2.4 V dc
at 400A
0.5 V dc
at 16 mA
15 45 to 55
50 40 25
05 2.5 MHz to
5 MHz
+5
0.25
50 source sink 15 45 to 55
50 40 25
06 5 MHz to
10 MHz
+5
0.25
35 15 40 to 60
50 40 25
07 10 MHz to
20 MHz
+5
0.25
25 15 40 to 60
50 40 25
08 20 MHz to
30 MHz
+5
0.25
35 5 40 to 60
50 40 25
09 30 MHz to
50 MHz
+5
0.25
50 5 40 to 60
50 40 25
10 50 Hz to
1 kHz
+5
0.25
158 15 40 to 60
50 40 25