MIL-PRF-55310/11G
4
TABLE I. Dash numbers and operating characteristics.
Frequency-voltage tolerance: 1 ppm maximum for a 10 percent change in supply voltage. Measurements taken
at reference temperature and operating temperature range end points.
Frequency aging: Measurements shall be taken at +70C 0.2C at intervals of not more than every 72 hours for a
minimum of 30 days.
0.1 ppm per 30 days, maximum.
0.5 ppm per 90 days, maximum. 2
/
5 ppm per year, maximum. 2/
Terminal strength: Method 211 of MIL-STD-202
, test condition C.
Applied force: 2 pounds each terminal.
Bends: Five at 45 degrees each.
Frequency-environmental tolerance: Not applicable.
Vibration, sinusoidal: In accordance with MIL-PRF-55310
and method 204 of MIL-STD-202.
Nonoperating: Test condition D.
Operating: Not required.
Ambient pressure:
Nonoperating: In accordance with MIL-PRF-55310
.
Operating: Method 105 of MIL-STD-202
, test condition C.
2
/ This if a performance requirement of the oscillator. Support data shall be presented to the qualifying activity
showing that this requirement shall be met.
Dash
num-
Output
frequency
Supply
voltage
Input
current
Output voltage Rise
and
Duty
cycle
Frequency-temperature
tolerance (ppm)
ber range (max) Logic: 1
(min)
Logic: 0
(max)
fall
times
(max)
-55C
to
+125C
-55C
to
+105C
-20C
to
+70C
A B C
MHz V dc mA V dc V dc ns percent
01 .05 through 6 +15 35 13 2 30 45 to 55
50 40 25
02 6 through 10 +15 40 13 2 30 45 to 55
50 40 25
03 .05 through 6 +12 25 10 1 60 45 to 55
50 40 25
04 6 through 10 +12 30 10 1 60 45 to 55
50 40 25
05 .05 through 6 +10 20 9.5 0.5 60 45 to 55
50 40 25
06 6 through 10 +10 20 9.5 0.5 60 45 to 55
50 40 25