User`s manual
User’s manual of remote client software
Fig 2.5.31
2.5.3.2 Remote configure interface of ME series
2.5.3.2.1 Server parameters configuration
Select “server configuration” in the remote setup interface, show as Fig 2.5.32.
Server name: not more than 24 characters, 12 Chinese at most.
Cycle record: if you want to overwrite after the HDD is full, just select “YES”, if you want to
stop record after the HDD is full, just select “NO”.
Administrator password, super operator password and operator password: the different level
operator has different password. The password can not be null.
IP address, port and mask: server static IP, port and mask. The default port is 8000.
NIC type: here are some options such as 10M/100M Auto and so on.
DNS host IP: the DNS server IP should be inputted while the server use private domain.
Multicast IP: when you use the multicast, you should input a D-class IP. Between 224.0.0.0
to 239.255.255.255.
Gateway: if client software need go through the gateway to connect the server, you should
input a gateway.
NAS host IP and NAS directory: if use network store server, just input the NAS IP and the
directory.
Remote host IP and port: IP and port of the PC that used for receiving alarm information.
- 45 -