User`s manual
User’s manual of remote client software
user name and password.
Http port: it will be used when you use the IE to connect our server.
The MAC address and PPPOE IP can’t be modified.
Server version information:
Firmware version, Hardware version, Encode version and Front panel version can’t be
modified.
After the configuration is finished, click “confirm”. If need reboot, just click “Reboot”
button.
2.5.3.1.2 Channel configuration
Select “channel configuration” in the interface. Show as Fig 2.5.19.
Select channel: select one channel of the server.
Channel name: it can be modified, 32 characters at most or 16 Chinese words.
Stream type: if select main stream in the channel properties interface and both the video and
audio should be recorded, please select “video & audio”, if else just select “video” .Sub stream is
for network transmission.
Max bit rate: You can select 32kbps, 48kbps, 64kbps, 80kbps, 96kbps, 128kbps, 160kbps,
192kbps, 224kbps, 256kbps, 320kbps, 384kbps, 448kbps, 512kbps, 640kbps, 768kbps, 896kbps,
1Mbps, 1.25Mbps, 1.5Mbps, 1.75Mbps, 2Mbps and Self-definition.
Frame rate: Full (PAL: 25FPS NTSC: 30FPS), 20, 16, 12, 10, 8, 6, 4, 2, 1, 1/2, 1/4, 1/8,
1/16.(notice: 15,18 and 22 are special options and only some special server have. )
Image quality: 6 options (only effective for variable bit rate type).
Resolution: Default is CIF, other options are QCIF, 2CIF, DCIF and 4CIF. Only QCIF and
CIF can be select when it is sun stream.
Bit rate type: Variable and Fixed can be selected.
Frame type: BBP and P can be selected.
Recording schedule:
Enable “schedule” option, you can setup the record time, prerecord time, post record time.
Click “setup” button to enter into recording schedule setup dialog box shown as Fig 2.5.20.
Select record mode, if select all day record, only record type can be setup.
If finish the setup, click “confirm” button to return. Click “cancel” to return if you do not
want to save the configuration.
PreRec. time: Recording time options before alarm happened. The options are include no
prerecord, 5s, 10s, 15s, 20s, 25s, 30s, maximum.
Post record time: Recording time options after alarm stopped. The options are include 5s, 10s,
30s, 1min, 2min, 5min, 10min.
- 35 -