User guide
Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.6.R02 page 99
General
Problem Reports
PR 51067
A Switch based telnet client only supports a single user at a time on an OS7000 series switch. If one user
already has started using the telnet client, and a second user attempts to use the switch based telnet client
at the same time, a message is generated informing the second user that the client is already in use.
The actual message sent is: "Telnet is already in use."
Workaround: There is no known workaround at this time.
PR 51088
The more command is not supported on multiple user sessions on an OS7000 series switch. Therefore,
only one instance may be active on a switch at a time. If a second user attempts to use more, when it is
already active, he/she receives the message: more is currently in use, try again later.
Workaround: There is no known workaround at this time.
PR 52676
Blocking sockets need to be released when a remote slot goes down on an OS7000 series switch.
Workaround: There is no known workaround at this time.
PR 55967
Only terminal ID vt100 is supported on an OS7000 series switch. User must set tty terminal type to vt100
to support some switch software that uses ASCII escape codes. The 'vi' editor is an example.
Workaround: There is no known workaround at this time.
PR 59510
The time for 10/100 ports to auto-negotiate depends on the number of such ports configured in the system.
The more the number of ports configured for auto-negotiation, the longer it takes before they all auto-
negotiate. This is observed only at bootup condition.
Workaround: There is no known workaround at this time.