User guide
Open Problem Reports and Feature Exceptions
page 78 OmniSwitch 6600/7000/8800—Release 5.1.6.R02
PR 90160
On an OS7000 series switch, when a URL file address is added to an SLB probe, a '/' is added.
Workaround: There is no known workaround. This functionality helps when sending the HTTP GET.
Since the parameter is an offset to a file on the HTTP server, we made sure there was a '/' for the GET.
UDP Relay
Problem Reports
PR 77401
On an OS7000 series switch, if the lease time expires for a particular IP address used by one switch, the
server is out of new IP addresses, and another switch requests an IP address, then the server gives out the
IP address whose lease has expired to this new switch. Thus, resulting in duplicate IP addresses on the two
switches.
Workaround: Increase the lease time on the server or configure a larger pool of addresses on the server.
PR 83947
On an OS7000 series switch, show ip udp relay service has zero value for statistic.
Workaround: There is no known workaround at this time.
PR 84359
If a VLAN’s router IP address is changed on an OS7000 series switch, UDP relay agent still has the previ-
ous IP.
Workaround: Disable the relay service on the VLAN using the no ip udp relay service vlan, then enable
the relay service on the VLAN again using the ip udp relay service vlan command.
PR 84471
On an OS7000 series switch, the ip_id field gets changed.
Workaround: There is no known workaround at this time.
PR 84500
On an OS7000 series switch, once a UDP framed is relayed, its TTL value is always set to 32 secs (hex
20).
Workaround: There is no known workaround at this time.