User guide
Open Problem Reports and Feature Exceptions
page 70 OmniSwitch 6600/7000/8800—Release 5.1.6.R02
PR 92573
The configured High Availability VLAN bandwidth is global on a switch and not per VLAN even though
the CLI command is on a per VLAN basis. The latest High Availability VLAN bandwidth configured
determines the global bandwidth.
Workaround: There is no known workaround at this time.
PR 92575
The High Availability VLAN Bandwidth is granted on a per ingress slot basis. When ingress ports are on
different slots, the transmission rate on egress ports can be higher than the configured bandwidth.
Workaround: There is no known workaround at this time.
PR 92628
Once a port is added to an ingress list or tagged for a High Availability VLAN, all other ports in the same
slot behave like ingress ports.
Workaround: There is no known workaround at this time.
Basic IP Routing
Problem Reports
PR 57299
The unloading and reloading of RIP/BGP/OSPF is not supported on all OmniSwitch platforms.
Workaround: Reboot the switch for reloading of the operation protocol.
PR 58974
Changing the Ethernet encapsulation from eth2 to snap while running traffic, does not take effect until
manual route cache clear is performed on an OS7000 series switch.
Workaround: There is no known workaround at this time.
PR 59475/59877
Changing from multiple router MAC to single router MAC mode and vice-versa, requires a reboot on an
OS7000 series switch.
Workaround: There is no known workaround at this time.
Layer 3