User guide

Open Problem Reports and Feature Exceptions
page 68 OmniSwitch 6600/7000/8800—Release 5.1.6.R02
PR 69656
Unicast frames will be flooded on an OmniSwitch 8800 switch until all the MAC addresses are learned in
both the source and destination CAMs.
Workaround: There is no known workaround at this time.
PR 70811
A default VLAN might come up in operational state when it is disabled to accommodate group mobility.
Workaround: There is no known workaround at this time.
PR 70954
The first IPX encapsulation learned on a fresh OS6624/6648 switch becomes the only encapsulation that
can be learned until the switch is rebooted regardless of the encapsulation selected in the IPX (ipx-e2, ipx-
llc, or ipx-novell) protocol rule.
Workaround: There is no known workaround at this time.
PR 71665
Setting the egress flood limit to zero will still allow a small number of flood packets to egress the port.
Workaround: There is no known workaround at this time.
PR 72223
Autonegotiation is disabled if either speed or duplex is set to non-autonegotiation on the OS7-ENI-C24,
OS7-ENI2-C24 and OS8-ENI-C24.
Workaround: There is no known workaround at this time.
PR 73334
When the configuration for a range is applied on an OmniSwitch 8800 switch, and if there is an error in
the middle of the group configuration (all slot, groups of ports), the rest of the configuration will not apply
from the point of error.
Workaround: Apply the configuration from the next valid starting point (e.g. next valid port).
PR 73367
Mobile and default VLAN traffic flow is not effective if the ingress frames to the OS6600 series switches
contain IEEE 802.1Q VLAN tagging, and mobile-tagging is disabled for the destination VLAN; trans-
parent tagging is not supported.
Workaround: There is no known workaround at this time.