Problem Reports
PR 54327
If the VLAN ID of the AV-Client dialog box is entered incorrectly twice on an OS7000 series switch, one
receives the following error: "Failure during DoSendData () call" and the AV-Client dies. A similar
behavior is observed with unsuccessful authentication. For example, unknown user on the remote authen-
tication server.
Workaround: Reboot of the PC is required.
PR 55491
On a mobile port with mac-port-ip (and other ip) rules, on an OS7000 series switch, changing a station's IP
address without the layer 2 address being aged out or flushed by link down, results in the station remain-
ing in the same VLAN despite the change.
Workaround: There is no known workaround other than aging or pulling the link. The layer 3 address is
only examined when the MAC address is not source learned, which is the cost of wire-speed group mobil-
ity.
PR 58160
Sometimes a mobile VLAN port association remains, showing the blocking mode. This behaves properly
on the NI, but the CMM still shows the VLAN port association, as existing. The blocking property indi-
cates that it is no longer forwarding the correct state. The mobile VPA stays as long as there is a continu-
ous stream of DHCP traffic incoming on the NI ports.This is as per design, as DHCP traffic is expected to
be in short spurts and not continuous in nature as this test-case suggests.
Workaround: There is no known workaround at this time.
PR 59422
The show interfaces slot/port traffic command displays the values irrespective of the port state (up or
down) on an OS7000 series switch, unlike the other interface statistics commands, which display the
statistics only if the port is up.
Workaround: There is no known workaround at this time.
PR 59883
Flash-synchro does not synchronize the IP address of the EMP port on an OS7000 series switch.
Workaround: There is no known workaround at this time.