Open Problem Reports and Feature Exceptions
page 54 OmniSwitch 6600/7000/8800—Release 5.1.6.R02
PR 81288
On an OS7000 series switch, LACP packets stop being exchanged after enabling the backpressure
command.
Workaround: Do not run this command with LACP configured.
PR 81416
On an OS7000 series switch, changing LACP values on run time makes the ports not join the link aggre-
gate.
Workaround: Do not change LACP values on the run time. If needed, delete the port and add again to
make a modification.
PR 81531
On OS6600 switches, sometimes multicast flow stops when link aggregate ports are added and deleted
multiple times.
Workaround: There is no known workaround at this time.
PR 81650
When misconfigured LACP ports are connected to LACP ports which send LACP pdus, the LACP pdus
parameters can make the port join a wrong link aggregate.
Workaround: When configuring LACP values, make sure that each end of the link aggregate is config-
ured properly.
PR 81722
If more ports are configured than the actual link aggregate size, some or all of the ports may not join the
dynamic link aggregate.
Workaround: Do not configure more ports than the actual link aggregate size.
PR 81736
On OS8800 switches, when link aggregate ports with the same configuration other than the size of the link
aggregate has any of the active ports go down, the non-joining ports do not join the aggregate.
Workaround: Do not configure more ports than the actual link aggregate size.