User guide
Open Problem Reports and Feature Exceptions
page 52 OmniSwitch 6600/7000/8800—Release 5.1.6.R02
PR 77684
On an OS7000 series switch, replacing second generation NIs with first generation NIs causes ports not to
come up.
Workaround: If second generation boards are hotswapped with first generation boards, some link aggre-
gate ports may not come up. Replace second generation interfaces with second generation interfaces only.
PR 77693
An OS7000 series switch is not able to pass traffic through a link aggregate port if the traffic originates
from the same slice as the link aggregate.
Workaround: Do not use the same NI port to pass the bridged traffic through the same slice ports config-
ured as link aggregate.
PR 78281
If second generation NI ports come up first, first generation NI ports cannot be added to the same aggre-
gate.
Workaround: When configuring mixed NI version ports in the same aggregate, make sure first genera-
tion ports are added first before adding second generation ports.
PR 78374
After hotswapping a second generation NI with a first generation NI, spanning tree detects a misconfigura-
tion.
Workaround: Do not hotswap a second generation board with a first generation board if link aggregate is
configured across multiple boards.
PR 78752
On OS6600 series switches, deleting actor system id on a LACP port makes the display set to all Zeroes.
Workaround: LACP ports need to be set with a non zero system id. Otherwise, the default system id will
be used. Delete the port and add again to use the default system id.
PR 78804
On OS6600 series switches, changing LACP parameters on runtime affects the LACP mechanism.
Workaround: Do not change the LACP port parameters on runtime. If a modification is needed, delete
and add the port again.