PR 91014
On an OS8800 switch, the force tag internal disable is not working. The original VLAN id in an 802.1q
packet ingressing an untagged port is replaced with the default VLAN of the ingress port when this VLAN
id is tagged on the egress port.
Workaround: There is no known workaround at this time.
Bridging
Problem Reports
PR 75329
On an OS7000 series switch, the user guide has a bug which requires the custom rule mask values to be in
nibble patterns (f). The custom rule mask values can be any combination of bit patterns and do not have to
be defined as fs for nibbles.
Workaround: There is no known workaround at this time.
PR 84780
In WebView, Physical > Ethernet > Interface Configuration > General "Modify" window might display a
"Set operation finished successfully!" message. However, the changes are not made to the table.
Workaround: Use the "Multiple Modify" window and select the desired slot/port to perform the changes.
PR 86084
The configuration file from 5.1.4 or older releases might not be compatible for autonegotiation if either
speed or duplex is set to non-auto.
On such releases, autonegotiation is automatically disabled and saved in the boot.cfg configuration file.
Workaround: Enable autonegotiation and save the configuration.
PR 88974
On an OS7000 series switch, in case of a MAC-IP-PORT binding rule violation, if the MAC-address is the
cause of a rule violation, then the violating flow is filtered on the default VLAN of the port; if the IP
address is the cause of the rule violation, then the violating flow is filtered on the mobile VLAN config-
ured in the rule.
Workaround: There is no known workaround at this time.
PR 89596
On an OS6600 series switch, group mobility only recognizes Ethertype 0x6003 for DECNET protocol
classification. All other DECNET Ethertypes are treated as unknown or default protocol types.
Workaround: There is no known workaround at this time.