User guide

Open Problem Reports and Feature Exceptions
page 42 OmniSwitch 6600/7000/8800—Release 5.1.6.R02
PR 89093
On an OS6600 series switch, in WebView, Networking > IP Multicast users with only read-write permis-
sions on IPMS, IPMR, and Web Management cannot add a static neighbor/groups/querier due to the
VLAN and slot/port drop-downs being empty (insufficient permissions).
Workaround: Add read-only permissions to include VLANs and ports, or use corresponding CLI
commands (VLAN, slot/port will have to be known as well).
PR 89576
In WebView, Networking > IP > OSPF > Interfaces > Area page shows the wrong value for "Priority" on
the table.This applies to all platforms.
Workaround: Look at value from the "Modify" page.
PR 89965
When an OS6600 series switch is under attack, sometimes it temporarily runs out of system resources. The
HTTP server in this case fails to send out the trap.
Workaround: There is no known workaround at this time.
PR 90643
On an OS8800 switch, in WebView, Networking > IP > ARP > Create ARP > Proxy Add page Name
appends extra text to the end.
Workaround: Leave Name blank on the Add page and use the Modify page to change to the desired
Name.
PR 90754
On an OS7000 series switch, WebView does not provide the necessary web page for adding and remov-
ing IPv6 prefixes.
Workaround: Use the CLI to add IPv6 prefixes.
PR 91961
In WebView, Networking > IP > BGP4 > Neighbors > Configuration modify page, Local Interface Name
cannot be changed back to None.
Workaround: Delete the neighbor and add the same again without specifying a Local Interface name.
PR 91962
In WebView, Networking > IP > BGP4 > Neighbors > Administration modify page, the field "Remove
Private AS" has the wrong drop-down options.
Workaround: There is no known workaround at this time.